We offer a wide range of enthalpy exchangers suitable for most heat recovery units. If you can't find the right model, don't hesitate to contact us – we will be happy to help!

Close
  • -25%

Nilan Comfort 300 Top – CORE enthalpy exchanger

Premium enthalpy exchanger from the German brand CORE.

$721.45
i
The amount of VAT applied is 0% for the country United States.
Sale ends soon:
$961.93 Save 25%
Quantity
IN STOCK – READY TO SHIP

The photo may not depict the actual design of the exchanger. This enthalpy exchanger is 100% compatible with the heat recovery unit Nilan Comfort 300 Top and, thanks to its properties, can offer better performance than the original enthalpy exchanger. However, it is not an original enthalpy exchanger supplied by the unit manufacturer.

If we have any doubts about whether you have ordered the correct exchanger type, we will contact you before shipping to fine-tune everything together.


CORE F-ERV — the latest generation of enthalpy exchangers

The CORE F-ERV enthalpy exchangers represent the most advanced technological level among ERV exchangers. They use a revolutionary formable polymer membrane that enables efficient transfer of heat and moisture back into the supply air. At the same time, it prevents viruses, bacteria, odors, or mold from returning indoors — everything is exhausted outside with the extract air.

Thanks to lower weight, higher efficiency, and improved design, they are suitable not only for standard residential systems but also for large air handling and industrial units. F-ERV is the direct successor and evolution of the C-ERV series.


Results from the manufacturer's selection software

Input conditions according to EN 308: 2022

  • Air volume flow: 150 m3/h.
  • Outdoor air temperature: 5 °C
  • Outdoor air relative humidity: 72 %
  • Extract air temperature: 25 °C
  • Extract air relative humidity: 50 %
  • Pressure drop: 30 Pa
  • Temperature efficiency: 83.2%
  • Moisture efficiency: 69.6%

Advantages of F-ERV compared to C-ERV

  • Significantly higher efficiency in heat and moisture transfer
  • Next-generation formable membrane = lower pressure drops
  • Lighter construction → easier handling and installation
  • Lower energy consumption during defrosting → less condensation
  • More environmentally friendly, better material recyclability
  • Awarded the PLUS X AWARD for innovation, quality, user comfort, functionality, and ecology

What makes CORE technology unique

  • Transfers heat and moisture, stabilizes indoor climate
  • Consistently high efficiency even at low outdoor temperatures
  • The membrane blocks viruses, bacteria, mold, and odors from extract air
  • Design prevents condensate accumulation inside the exchanger
  • Long service life, washable surface, easy maintenance


RekupeX Evaluation

  • CORE exchangers are characterized by low weight, ensuring easy handling and smooth installation.
  • They feature a simple plastic chassis with a smooth surface and rounded corners, which is a major advantage in some units — especially when inserting the exchanger into limited space.
  • Another benefit is high efficiency combined with low pressure drop, contributing to economical operation.
  • The disadvantage is availability only for a limited number of heat recovery units.
CORE Detail
CORE

Data sheet

Unit manufacturer
Nilan
    What is the difference between enthalpy heat exchangers from different manufacturers?

    Enthalpy Heat Exchangers for Ventilation Units – Comparison

    At Rekupex, we offer enthalpy heat exchangers for a wide range of ventilation units from various manufacturers. We continuously expand our range to cover as many commonly used ventilation systems on the market as possible.


    Our customers also play an important role in expanding the product range by helping us identify new types of ventilation units and their compatible enthalpy heat exchangers. Thanks to this cooperation, we can continuously develop our offer and adapt it to the real needs of users. Thank you for your feedback and suggestions.


    To make it easier for you to understand the differences between enthalpy exchangers from RECUTECH, ZERN Engineering, CORE, and AIRWOODS, we have prepared a clear technical comparison of exchangers of the same size 366 × 366 × 400 mm, which can be directly compared thanks to their identical dimensions.


    The overview also includes three key diagrams, which make it possible to compare exchanger behavior depending on the air volume flow rate:

    • pressure drop at different air flow rates
    • heat transfer efficiency
    • moisture transfer efficiency

    Technical Comparison Diagrams

    Click on the diagram to open the high-resolution detail.

    Diagram of pressure drop of enthalpy heat exchangers

    Pressure drop vs. air volume flow rate

    Diagram of heat transfer efficiency of enthalpy heat exchangers

    Heat transfer efficiency


    Moisture transfer efficiency

    Input conditions according to EN 308:2022

    • Outdoor air temperature: 5 °C
    • Outdoor air relative humidity: 72 %
    • Extract air temperature: 25 °C
    • Extract air relative humidity: 50 %

    The results were obtained using the selection and design software of the individual manufacturers.


    Comparison of Enthalpy Heat Exchangers (366 × 366 × 400 mm)

    The input parameters are unified according to EN 308:2022, unless stated otherwise. For AIRWOODS, different input values according to the manufacturer’s documentation were used, therefore the inputs differ.

    On mobile, swipe the table sideways.

    Parameter CORE F-ERV 366 ZERN EC-EX6 366 RECUTECH METALPIC RKF+16 AIRWOODS WXL-LB 366*
    Exchanger photo CORE F-ERV 366 – photo of the enthalpy heat exchanger
    Click to enlarge

    Click to enlarge

    Click to enlarge

    Click to enlarge
    Input conditions
    Outdoor air temperature [°C] 5 5 5 -5
    Outdoor air relative humidity [%] 72 72 72 25
    Extract air temperature [°C] 25 25 25 25
    Extract air relative humidity [%] 50 50 50 80
    Performance at air volume flow rate of 150 m³/h
    Pressure drop [Pa]¹ 28 37,65 25,18 ⭐ best 29,9
    Temperature efficiency [%]¹ 84,1 82,36 87,1 ⭐ best 85,75
    Moisture efficiency [%]¹ 70,9 58,96 66,5 75,73 ⭐ best
    Performance at air volume flow rate of 400 m³/h
    Pressure drop [Pa]¹ 134 141 114 ⭐ best
    Temperature efficiency [%]¹ 77,5 71,4 78,3 ⭐ best
    Moisture efficiency [%]¹ 51,7 47,84 58 ⭐ best
    Construction and materials
    Exchanger casing material Unspecified plastic HPS (High Pressure Structure) Corrosion-resistant aluminum Unspecified plastic
    Exchanger construction type Polymer plate exchanger Polymer plate exchanger Metal enthalpy heat exchanger ⭐ Polymer plate exchanger
    Enthalpy membrane carrier The membrane is part of the supporting material HPS (High Pressure Structure) Aluminum carrier (expanded metal) Plastic separators
    Type of enthalpy membrane Formable polymer membrane (integrated in the plates) Polymer microporous membrane Ion-exchange membrane (METALPIC) Polymer microporous membrane
    Transport packaging Polystyrene protection + cardboard box Polystyrene protection + cardboard box Wooden transport crate (also suitable for storing the original exchanger) Polystyrene protection + cardboard box
    REKUPEX evaluation
    Overall evaluation High efficiency at lower flow rates. Thanks to its low weight and smooth casing, it places minimal demands on installation. Robust and mechanically durable construction. Good availability of dimensions for a wide range of ventilation units. All-aluminum exchanger with METALPIC membrane. Excellent efficiency / pressure drop ratio. Highest heat transfer efficiency and, at higher air volume flow rates, also very good moisture transfer. Proven exchangers used by a number of European unit manufacturers thanks to a good price / performance ratio.
    Strengths Very good moisture efficiency at lower air flow rates. Low weight. Very solid workmanship and high mechanical durability. Very good results at medium and higher flow rates. Low pressure drop across the entire range. Favorable price while maintaining solid parameters.
    Possibility of adapting exchanger dimensions Limited Limited Very wide possibilities for adapting dimensions ⭐ Limited
    Availability of newly identified and less commonly used exchangers Limited availability Good availability Excellent availability ⭐ Limited availability
    Note about the manufacturer RECUTECH provides excellent customer and technical support, making it possible to effectively design, adapt, and integrate exchangers into a wide range of ventilation units. Thanks to the robust construction with an aluminum casing, the exchangers are also very suitable for retrofit applications and modernization of older ventilation units.
    Certification and compliance
    Eurovent YES
    DIN ISO 9001:2015 YES YES YES
    Hygiene certificate VDI 6022 VDI 6022 VDI 6022 ANTI BACTERIAL + Antimicrobial test report
    RoHS YES YES YES YES
    REACH YES YES YES YES
    Data source and calculation
    Exchanger manufacturer CORE GmbH ZERN Engineering RECUTECH AIRWOODS
    Availability (sales) www.rekupex.cz www.rekupex.cz
    www.rekupex.de
    www.rekupex.cz
    www.rekupex.de
    On request by e-mail: info@rekupex.cz
    Calculated size 366 × 366 × 400 mm 366 × 366 × 400 mm 366 × 366 × 400 mm 366 × 366 × 400 mm
    Calculation software Online (manufacturer’s website) Online (manufacturer’s website) Offline design selector Offline design selector
    Calculation date 3 March 2026 3 March 2026 3 March 2026 3 March 2026

    ⭐ best value in the given category

    ¹ The values were determined based on calculations in the manufacturers’ selection programs under the input conditions defined by EN 308:2022.

    * Different input values according to the manufacturer’s documentation were used for AIRWOODS.


    REKUPEX Recommendation

    Based on our long-term experience with the design and integration of enthalpy heat exchangers into various types of ventilation units, we particularly recommend RECUTECH exchangers, which stand out thanks to their very good efficiency / pressure drop ratio, robust construction, and above all excellent technical support from the manufacturer.

    Thanks to this cooperation, the exchangers can be easily adapted to a wide range of ventilation units, including retrofit installations in older equipment.


    Which Enthalpy Heat Exchanger Should You Choose?

    The comparison shows that individual manufacturers optimize their exchangers for different operating conditions. Some exchangers achieve very good results especially at lower air volume flow rates, while others are optimized for medium and higher air flow rates.

    When choosing an enthalpy heat exchanger, it is therefore important to consider not only the efficiency itself, but also pressure drop, exchanger construction, compatibility with the ventilation unit, the possibility of adapting dimensions, and the availability of replacement exchangers.


    Frequently Asked Questions About Enthalpy Heat Exchangers

    What is the difference between an enthalpy heat exchanger and a standard heat recovery exchanger?

    An enthalpy heat exchanger transfers not only heat, but also part of the moisture from the extract air to the supply air. This helps maintain a more comfortable indoor humidity level, especially during the winter season.

    What is the typical efficiency of an enthalpy heat exchanger?

    The temperature efficiency of modern enthalpy heat exchangers usually ranges approximately between 75–90 %.
    The moisture transfer efficiency is usually lower and generally ranges approximately between 40–75 %.

    Both values are significantly influenced by the exchanger design, membrane quality, and especially the air volume flow rate at which the exchanger is operated.

    Can an enthalpy heat exchanger be installed in an older ventilation unit?

    Yes, at RekupeX we not only sell exchangers, but also technically adapt them for specific ventilation units. We manufacture our own sealing and mounting profiles, and if necessary we also produce reduction casings. Thanks to this, we can offer an enthalpy replacement even for older ventilation units, where compatibility may at first glance appear problematic. A typical example is exchangers for Atrea units.


    Note: The technical data and graphs presented in this overview were prepared based on the technical documentation of the individual manufacturers and the results of their selection or design tools. Although we have made every effort to ensure maximum accuracy, individual values may vary depending on the specific operating conditions, unit configuration, or updates to the data provided by the manufacturers.

    The stated REKUPEX evaluation is based on our long-term practical experience with the design, sale, and integration of enthalpy heat exchangers into various types of ventilation units.

    If any manufacturer identifies an inaccuracy or has a comment regarding the stated data, we will be grateful for the notice and will be happy to adjust the data.


    If you are unsure which enthalpy heat exchanger is suitable for your ventilation unit, do not hesitate to contact us. We will be happy to help you choose the right solution.


    Should I use an enthalpic heat exchanger in summer as well, or only in winter?

    An enthalpic heat exchanger should be used all year round. In winter, it prevents excessive drying of the indoor air, and in summer, it helps maintain comfortable humidity and temperature by reducing heat transfer and returning part of the moisture to the fresh supply air. This increases comfort and saves energy in every season.


    Is the use of an enthalpic heat exchanger safe for health?

    Yes, the use of an enthalpic heat exchanger is completely safe. The membrane is designed to allow only water vapor molecules to pass through, while blocking bacteria, odors, and harmful substances. All enthalpic heat exchangers we offer are hygienically tested and certified.


    How does an enthalpic heat exchanger work?

    An enthalpic heat exchanger works on the principle of counterflow air streams. During ventilation, two separate airflows meet inside – the warm, humid exhaust air from indoors and the cold fresh air from outside. A special membrane transfers both heat and water vapor from the exhaust air to the incoming fresh air without mixing the two streams. This way, fresh air enters the home with a more comfortable temperature and humidity, improving comfort while saving energy.


    Is it guaranteed that using an enthalpic heat exchanger will achieve ideal humidity levels?

    An enthalpic heat exchanger will always help improve indoor humidity, as it transfers part of the moisture from exhaust air back into the fresh supply air. It cannot be guaranteed that ideal levels (typically 40–60%) will be achieved, since the final humidity also depends on other factors – such as household habits, number of occupants, natural moisture sources, and outdoor climate conditions.

    However, we can guarantee that humidity will improve, because it is physically impossible for the return of moisture not to contribute to higher values.


    How long does it take to increase humidity in my home when using an enthalpic heat exchanger?

    An enthalpic heat exchanger does not generate humidity – it maximizes the transfer of humidity from exhaust air into fresh supply air. If you previously used a standard exchanger, not only the air but also the building structure (walls, ceilings, floors) and porous materials became dry. This means it may take some time for humidity levels to recover, so patience is necessary.

    Every enthalpic exchanger we supply is fully functional and improvement is guaranteed. We recommend keeping natural humidity sources (plants, cooking, drying clothes). If you use humidifiers, continue using them until the humidity rises to a comfortable level with the enthalpic exchanger, after which they can be reduced.


    Can I speed up the return of humidity?

    Yes. Unlike a standard exchanger, an enthalpic heat exchanger transfers part of the humidity back into the fresh air. This process is gradual, but you can speed it up by adding humidity – either naturally (plants, drying clothes, washing floors) or with humidifiers. Once the humidity has returned to a stable, optimal level, additional humidification can be reduced.


    Can an enthalpic heat exchanger increase humidity above optimal levels?

    No, an enthalpic heat exchanger does not generate humidity by itself. It only transfers part of the moisture from the exhaust air back into the fresh supply air. If humidity in your home is too high, the cause lies elsewhere (e.g., insufficient ventilation, drying clothes indoors without venting, or residual construction moisture). The enthalpic exchanger helps balance humidity and prevents extreme fluctuations.


    Does an enthalpy heat exchanger increase humidity in a house?

    Does an enthalpy heat exchanger increase humidity in a house?

    Yes, an enthalpy heat exchanger can transfer part of the moisture from exhaust air back into the supply air, helping to increase indoor humidity. This is not just a theoretical feature – it has been confirmed in real-world operation.

    In an independent test carried out by an experienced user in their home with an AEREX ventilation unit, the long-term issue was very dry indoor air, despite attempts to naturally increase humidity, for example by using a large number of plants.

    After installing the RECUTECH METALPIC enthalpy heat exchanger, there was a measurable increase in indoor humidity and an overall improvement in living comfort.

    Under typical conditions, indoor humidity increases by approximately 10–15% during the heating season. In ideal conditions, the increase can reach up to 25–30%, depending on indoor humidity levels, airflow settings, and building characteristics.

    Real measurement of indoor humidity with an enthalpy heat exchanger

    It is important to understand that an enthalpy heat exchanger does not generate moisture, it only transfers it from the exhaust air back into the supply air. Therefore, the effect is not immediate but builds up gradually over several days to weeks.

    This principle is based on physical laws and long-term real-world experience. That is why enthalpy heat exchangers are an effective solution for homes where ventilation systems cause excessive drying of indoor air.

    This is why an enthalpy heat exchanger is one of the most effective solutions for dry indoor air in homes with ventilation systems.


     What about mold formation in an enthalpic heat exchanger?

    Since an enthalpic heat exchanger also transfers humidity, it might seem that the risk of mold is higher. In reality, however, all moisture is carried away with the fresh air, so there is no risk of mold growth.

    Our recommendation is to never switch off the unit during the winter months, so that moisture is continuously removed. If you still need to shut down the unit, remove the exchanger, rinse it with clean water, dry it thoroughly, and only then reinstall it.


    Can I block the condensate drain if I replace a standard heat exchanger with an enthalpic one?

    No, never block the condensate drain.

    Even though enthalpic heat exchangers produce only a minimal amount of condensate due to moisture transfer, in severe frost and specific humidity conditions, condensate can still occur. Blocking the drain could cause irreversible damage to your unit.


    Can I install an enthalpic heat exchanger by myself?

    Yes, installation is simple. Just follow the instructions provided with your unit. As with a standard exchanger, it needs to be removed occasionally for cleaning – the process is the same, except that you put the enthalpic exchanger back in instead.


    I am not sure about the type of exchanger in my unit, or I did not find my unit type in your e-shop. What should I do?

    Feel free to contact us with any unit model. We will do our utmost to provide you with a 100% compatible exchanger, regardless of the type of ventilation unit you have.


    Why do you include a disclaimer stating that the product is not an original spare part?

    In any case, the exchangers we supply are identical to the original parts used by the unit manufacturers, and in many cases, our exchangers are even of higher quality. However, we must clearly state that we are not official distributors of spare parts from the unit manufacturers. Transparency is very important to us.


    Is it possible to insert the enthalpic heat exchanger into the unit in the wrong orientation?

    The enthalpic plate works the same from both sides, so the orientation of the plate itself does not matter. However, it is essential that after cleaning the exchanger is always reinstalled in the same orientation, ensuring that the channels for fresh air remain for fresh air and the channels for exhaust air remain for exhaust air.


    Does an enthalpic heat exchanger require more maintenance than a standard one?

    No, caring for an enthalpic heat exchanger is no more demanding than for a standard one. Maintenance is described in the user manual and in our video guide. In short: first vacuum the exchanger with a soft brush attachment, then rinse it with clean water (max. 50 °C). Never use compressed air or a pressure washer.

    After rinsing, allow all water to drain completely. Remaining moisture can be carefully blown out with a regular hairdryer, but always use cold air only. Once the exchanger is completely dry, place it back into the unit in the same orientation as before removal.

    We do not recommend using chemicals for cleaning. Only if disinfection is absolutely necessary may a weak solution of peracetic acid (CH₃CO₃H) at 0.1–0.2% concentration be used, followed by very thorough rinsing with clean water.


    I don’t know how to attach the sealing tape to the exchanger.

    The sealing tape must be applied around the perimeter of the exchanger, so that when inserted it presses firmly against the unit walls and prevents false air from being drawn in. The surface of the exchanger must be dry and clean before application. Always apply the tape straight, without gaps or folds, to ensure proper sealing.


5.0

How our customers rate us

Read verified reviews from those who have purchased from us.

All reviews

Zbozi.cz
Heureka.cz
Google
Rudi Rohde

Excellent product meets outstanding support and service.

I can recommend RekupeX without reservation, as I am personally very satisfied with the price-performance ratio and, above all, with the quality.

My review refers to their metal enthalpy heat exchanger.

Rolf Schernes

The RECUBOX® unit, as part of a ventilation system for heat removal from a laboratory room with a vacuum soldering furnace, is finally installed in time and does its work as planned and calculated, also thanks to the excellent support from the RekupeX team.

We no longer need any additional heating equipment for the room or for room ventilation.

Rafał Dąbrowski

Excellent communication, professional advice, everything was perfect.