We offer a wide range of enthalpy exchangers suitable for most heat recovery units. If you can't find the right model, don't hesitate to contact us – we will be happy to help!

Close

Recuperation heat exchanger RSX-P 03/100 (counter-flow hot air recuperator for air recovery)

Flow rate 170 m3/hour - Efficiency 93% - Pressure loss 240 Pa ....
Flow rate 120 m3/hour - Efficiency 93.6% - Pressure loss 139.4 Pa ....
Flow rate 50 m3/hour - Efficiency 95.1% - Pressure loss 39.2 Pa ....
Dimensions: 366 x 366 x 100 mm ....
Blade spacing: 3.2 mm ....
Weight: 2.02 kg ....
Material: plastic (HPS - high impact polystyrene)

Kč2,043
i
The amount of VAT applied is 0% for the country United States.
Quantity
In Stock

We keep the RSX-P 03/100 exchanger in stock and ship IMMEDIATELY after receiving your order.

RX, RX-P and RSX-P are modern counter-flow exchangers with fins made of durable aluminum and plastic. The counter-flow exchanger is the successor to the less
efficient cross-flow exchanger. The counter-flow exchanger does not transmit moisture or odors. Its efficiency exceeds 95%.
It is thanks to these properties, together with the tested tightness of each manufactured piece, that it finds its use both in heat recovery units of passive houses and in industrial applications.

  • Efficiency up to over 95%
  • Lower pressure losses compared to similar products on the market
  • Each exchanger tested for 100% tightness
  • New slat geometry
  • Ideal for residential units
  • HPS ultrasonically welded slats
  • Easy handling, thanks to handling straps
  • Parameters ensuring high SEC calculation value
  • Ideal for residential units
  • Eurovent, QMS, OHMS, EMS certification

         

EUROVENT

Exchanger parameters at: indoor/outdoor air ratio 1:1, outdoor air temperature -5°C and relative humidity 25%, indoor air temperature 25°C and relative humidity 80%, results from calculation software certified by the European company Eurovent

  • Flow rate 50 m3/hour - Efficiency 95.1% - Frontal velocity 0.5 m/s - Pressure loss - inlet - 26.2 Pa, outlet - 41.2 Pa
  • Flow rate 120 m3/hour - Efficiency 93.6% - Frontal velocity 1.5 m/s - Pressure loss - inlet - 139.4 Pa, outlet - 222.1 Pa
  • Flow rate 170 m3/hour - Efficiency 93% - Frontal velocity 2.1 m/s - Pressure loss - inlet - 240 Pa, outlet - 385.1 Pa

Upon request, we will send you complete exchanger parameters and resulting values by e-mail in the form of parameter sheets in .pdf format, under your desired conditions (humidity, temperature, air volume flow).

Graph of pressure loss - PD [Pa] versus volume flow AV [m3/h] - RSX-P 03/100 heat exchanger

Parameters for the average winter period in the Czech Republic

indoor/outdoor air ratio 1:1, outdoor air temperature 1°C and relative humidity 78%, indoor air temperature 25°C and relative humidity 28%, results from calculation software certified by the European company Eurovent

pd - av

Graph of the dependence of efficiency EFF [%] on the volume flow AV [m3/h] - exchanger RSX-P 03/100

Parameters for the average winter period in the Czech Republic

indoor/outdoor air ratio 1:1, outdoor air temperature 1°C and relative humidity 78%, indoor air temperature 25°C and relative humidity 28%, results from calculation software certified by the European company Eurovent

The heat recovery exchanger can be installed in any position in the unit (cabinet, box).rong>

heat recovery exchanger on a wide tray

Installation on a narrow tray.

Recommended slope of 3° to the waste heat outlet for good condensate drainage.

heat recovery exchanger on the front surface

Installation on the front surface

Recommended slope of 5° to the waste heat outlet for good condensate drainage.

heat recovery exchanger on a narrow tray

Installation on a narrow tray

This position is only possible if the entire weight of the exchanger does not rest on a narrow tray.

If you do not choose from our offer in the e-shop, there is no problem for us to price you any exchanger according to the table below.

exchangers dimensions and efficiency

Data sheet

Warranty length
36 months
EUROVENT certification:
YES
Slat material:
HPS (hygienic plastic)
Sheathing material:
Aluminum
Highest efficiency at output [m3/hour]:
0 - 170
Dimensions lxwxh [mm]:
366x366x100
Blade spacing [mm]:
3.2
Weight [kg]:
2.02
Operating temperature [°C]
-20 to +60

You might also like