Filter fabric M5, 20 mm, 350 g/m2
Filtration class M5... Density 350 g/m2 ... Thickness 20mm... Roll width 1.6 m... Selling per 1m2... Price listed for 1m2...
We offer a wide range of enthalpy exchangers suitable for most heat recovery units. If you can't find the right model, don't hesitate to contact us – we will be happy to help!
Flow rate 170 m3/hour - Efficiency 93% - Pressure loss 240 Pa ....
Flow rate 120 m3/hour - Efficiency 93.6% - Pressure loss 139.4 Pa ....
Flow rate 50 m3/hour - Efficiency 95.1% - Pressure loss 39.2 Pa ....
Dimensions: 366 x 366 x 100 mm ....
Blade spacing: 3.2 mm ....
Weight: 2.02 kg ....
Material: plastic (HPS - high impact polystyrene)
We keep the RSX-P 03/100 exchanger in stock and ship IMMEDIATELY after receiving your order.
RX, RX-P and RSX-P are modern counter-flow exchangers with fins made of durable aluminum and plastic. The counter-flow exchanger is the successor to the less
efficient cross-flow exchanger. The counter-flow exchanger does not transmit moisture or odors. Its efficiency exceeds 95%.
It is thanks to these properties, together with the tested tightness of each manufactured piece, that it finds its use both in heat recovery units of passive houses and in industrial applications.
![]()
![]()
![]()
![]()
Exchanger parameters at: indoor/outdoor air ratio 1:1, outdoor air temperature -5°C and relative humidity 25%, indoor air temperature 25°C and relative humidity 80%, results from calculation software certified by the European company Eurovent
Upon request, we will send you complete exchanger parameters and resulting values by e-mail in the form of parameter sheets in .pdf format, under your desired conditions (humidity, temperature, air volume flow).
Graph of pressure loss - PD [Pa] versus volume flow AV [m3/h] - RSX-P 03/100 heat exchanger
Parameters for the average winter period in the Czech Republic
indoor/outdoor air ratio 1:1, outdoor air temperature 1°C and relative humidity 78%, indoor air temperature 25°C and relative humidity 28%, results from calculation software certified by the European company Eurovent

Graph of the dependence of efficiency EFF [%] on the volume flow AV [m3/h] - exchanger RSX-P 03/100
Parameters for the average winter period in the Czech Republic
indoor/outdoor air ratio 1:1, outdoor air temperature 1°C and relative humidity 78%, indoor air temperature 25°C and relative humidity 28%, results from calculation software certified by the European company Eurovent

The heat recovery exchanger can be installed in any position in the unit (cabinet, box).rong>
Installation on a narrow tray. Recommended slope of 3° to the waste heat outlet for good condensate drainage. | |
Installation on the front surface Recommended slope of 5° to the waste heat outlet for good condensate drainage. | |
Installation on a narrow tray This position is only possible if the entire weight of the exchanger does not rest on a narrow tray. |
If you do not choose from our offer in the e-shop, there is no problem for us to price you any exchanger according to the table below.

Data sheet
Filtration class M5... Density 350 g/m2 ... Thickness 20mm... Roll width 1.6 m... Selling per 1m2... Price listed for 1m2...