Filter fabric M5, 20 mm, 350 g/m2
Filtration class M5... Density 350 g/m2 ... Thickness 20mm... Roll width 1.6 m... Selling per...
We offer a wide range of enthalpy exchangers suitable for most heat recovery units. If you can't find the right model, don't hesitate to contact us – we will be happy to help!
Flow rate 170 m3/hour - Efficiency 93% - Pressure loss 240 Pa ....
Flow rate 120 m3/hour - Efficiency 93.6% - Pressure loss 139.4 Pa ....
Flow rate 50 m3/hour - Efficiency 95.1% - Pressure loss 39.2 Pa ....
Dimensions: 366 x 366 x 100 mm ....
Blade spacing: 3.2 mm ....
Weight: 2.02 kg ....
Material: plastic (HPS - high impact polystyrene)
We keep the RSX-P 03/100 exchanger in stock and ship IMMEDIATELY after receiving your order.
RX, RX-P and RSX-P are modern counter-flow exchangers with fins made of durable aluminum and plastic. The counter-flow exchanger is the successor to the less
efficient cross-flow exchanger. The counter-flow exchanger does not transmit moisture or odors. Its efficiency exceeds 95%.
It is thanks to these properties, together with the tested tightness of each manufactured piece, that it finds its use both in heat recovery units of passive houses and in industrial applications.
Exchanger parameters at: indoor/outdoor air ratio 1:1, outdoor air temperature -5°C and relative humidity 25%, indoor air temperature 25°C and relative humidity 80%, results from calculation software certified by the European company Eurovent
Upon request, we will send you complete exchanger parameters and resulting values by e-mail in the form of parameter sheets in .pdf format, under your desired conditions (humidity, temperature, air volume flow).
Graph of pressure loss - PD [Pa] versus volume flow AV [m3/h] - RSX-P 03/100 heat exchanger
Parameters for the average winter period in the Czech Republic
indoor/outdoor air ratio 1:1, outdoor air temperature 1°C and relative humidity 78%, indoor air temperature 25°C and relative humidity 28%, results from calculation software certified by the European company Eurovent
Graph of the dependence of efficiency EFF [%] on the volume flow AV [m3/h] - exchanger RSX-P 03/100
Parameters for the average winter period in the Czech Republic
indoor/outdoor air ratio 1:1, outdoor air temperature 1°C and relative humidity 78%, indoor air temperature 25°C and relative humidity 28%, results from calculation software certified by the European company Eurovent
The heat recovery exchanger can be installed in any position in the unit (cabinet, box).rong>
Installation on a narrow tray. Recommended slope of 3° to the waste heat outlet for good condensate drainage. | |
Installation on the front surface Recommended slope of 5° to the waste heat outlet for good condensate drainage. | |
Installation on a narrow tray This position is only possible if the entire weight of the exchanger does not rest on a narrow tray. |