RECUBOX® RX 04/300 - 480 m3/h (recovery exchanger in...
Made in the Czech Republic .... Equipped with an RX 04/300 or RX-P 04/300 exchanger .......
We offer a wide range of enthalpy exchangers suitable for most heat recovery units. If you can't find the right model, don't hesitate to contact us – we will be happy to help!
Flow rate 480m3/hour - Efficiency 94.7% ....
Flow rate 280m3/hour - Efficiency 95.1% ....
Flow rate 90m3/hour - Efficiency 96% ....
Dimensions: 496 x 271 x 300 mm ....
Weight: 4.05 kg ....
Material: plastic (HPS - high impact polystyrene)
We keep the RX-P 04/300 exchanger in stock and ship IMMEDIATELY after receiving your order.
RX and RX-P are modern counter-flow exchangers with fins made of durable aluminum and plastic. The counter-flow exchanger is the successor to the less
efficient cross-flow exchanger. The counter-flow exchanger does not transmit moisture or odors. Its efficiency exceeds 92%.
It is thanks to these properties, together with the tested tightness of each manufactured piece, that it finds its use both in heat recovery units of passive houses and in industrial applications.
Exchanger parameters at: indoor/outdoor air ratio 1:1, outdoor air temperature -5°C and relative humidity 25%, indoor air temperature 25°C and relative humidity 80%, results from calculation software certified by the European company Eurovent
Graph of dependence of pressure loss - PD [Pa] on volume flow AV [m3/h] - exchanger RX-P 04/300
Parameters for the average winter period in the Czech Republic
indoor/outdoor air ratio 1:1, outdoor air temperature 1°C and relative humidity 78%, indoor air temperature 25°C and relative humidity 28%, results from calculation software certified by the European company Eurovent
Graph of the dependence of efficiency EFF [%] on the volume flow AV [m3/h] - exchanger RX-P 04/300
Parameters for the average winter period in the Czech Republic
indoor/outdoor air ratio 1:1, outdoor air temperature 1°C and relative humidity 78%, indoor air temperature 25°C and relative humidity 28%, results from calculation software certified by the European company Eurovent
The heat recovery exchanger can be installed in any position in the unit (cabinet, box).
Installation on a narrow tray. Recommended slope of 3° to the waste heat outlet for good condensate drainage. | |
Installation on the front surface Recommended slope of 5° to the waste heat outlet for good condensate drainage. | |
Installation on a narrow tray This position is only possible if the entire weight of the exchanger does not rest on a narrow tray. |
Thanks to the precise processing of the exchanger dimensions, their mutual combination is possible to increase efficiency and maximum air flow.
In order to respond to your orders as quickly as possible, we keep the most popular exchangers in stock in larger quantities.
If you do not choose from our offer in the e-shop, there is no problem for us to price you any exchanger according to the table below.
Data sheet
Made in the Czech Republic .... Equipped with an RX 04/300 or RX-P 04/300 exchanger .......